G34M G34MV User ManualSept 2003 Merit Series User ManualApril 2013 If you require further information on any of the products in the Lennox range, consult your local Lennox dealer, or call Lennox Australia on 13 23 50. Tina design suite v9 3 crack. Lennox/Armstrong/Concord and Ducane HS29-030S-5 Parts. Lennox/Armstrong/Concord and Ducane HS29-048-1 Parts. Mass effect 2 texture mods. 38568 Webb Dr. Westland, Michigan 48185 (734.
Comments
Lennox Hs29 036 2p
- hope this what you're looking for
Lennox equipment:
211= 1.5 ton, single phase
261= 2 ton, single phase
311= 2.5 ton, single phase
411= 3 ton single phase
413= 3 ton, 3 phase
461= 3.5 ton single phase
463= 3.5 ton, 3 phase
511= 4 ton single phase
513= 4 ton 3 phase
653= 5 ton 3 phase
The Wall strikes again!
To Learn More About This Professional, Click Here to Visit Their Ad in 'Find A Professional' - Lennox model numbers
14= 1 ton
21= 1-1/2 ton
26= 2 ton
31= 2-1/2 ton
41= 3 ton
46= 3-1/2 ton
51= 4 ton
65= 5 ton
So, your unit is a two ton model.
The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are the capacity, see above. The third number between the dashes indicates single phase or 3 phase, a single phase unit in your case. And the last numbers after the next dash will be the series number and sometimes a letter which indicates the voltage
So an HS29-261-1P is an air conditioner, 29 series, 2 ton, single phase, first revision (we call that the dash number, important when ordering parts) and the P stands for 208-230 volts.
-Jared - That's why...
..I love this site!
Thanks, guys. I knew I'd find an answer here.
Starch - Lennox heat pump
Hi. Anyone know if you can buy a new one of this model (HP19-261-3P) or at least a replacement?
Thanks. Garry1·Share on Google+ - I know someone that has a used one and is selling it!
- the hp19-261 is a r-22 hp 12 to 13.5 seer depending on indoor coil. replace with any 13 seer r-22 unit dry charge. If you can still find one.
- I have a lennox hs8-511-3ffp that the tech who came out to look at it said was failure to energize. what can i replace this with? or what do i need
- Need new system, outdoor unit, refrigerant lines & coil. This sucker dates to the early 70s. The refrigerant lines were a part of the system and can't be reused by a different A/C. Don't know what he means by failure to energize. Compressor won't start?1·Share on Google+
- It's been 35 years since I worked on one of them.Bob Boan
You can choose to do what you want, but you cannot choose the consequences. - Used to be all over the place here but now HS-8 units are pretty scarce. Most commonly left in apartments on there 25th compressor!
Sis had one, leaked like a sieve. 25 years ago she called and said fan motor was out, bring her another motor. No, I'm bring you a new A/C system. 25 years later she's on borrowed time but the current unit isn't leaking, just has a 1' square hole in the coil from dog piss. And it wasn't even her dog!